Unified Gutenprint/CUPS backend for various Dye-Sublimation photo printers
2012-10-28 11:18:29 -04:00
2020-01-23 18:29:00 -05:00
Copyright (c) 2007-2020 Solomon Peachy <pizza@shaftnet.org>
This free software comes with ABSOLUTELY NO WARRANTY and is licensed under
the GNU GPL (v3 or later); see the 'COPYING' file for more details.
SPDX-License-Identifier: GPL-3.0+
2012-10-28 11:18:29 -04:00
2013-07-18 21:23:34 -04:00
The latest version can be found at
2018-05-17 19:32:12 -04:00
http://git.shaftnet.org/cgit/selphy_print.git
2013-07-08 11:44:06 -04:00
For a list of known bugs and development plans, see:
http://bugs.shaftnet.org/index.php?project=4
2012-10-28 11:18:29 -04:00
***************************************************************************
If you do not have one of the printers listed below, this backend is
not relevant for you and you can just ignore all of this.
Supported Printers:
2013-07-18 21:23:34 -04:00
Canon SELPHY ES series
Canon SELPHY CP series
2016-12-13 22:54:26 -05:00
Ciaat Brava 21
Citizen CW-01
Citizen CW-02 / OP900II
2016-12-13 22:54:26 -05:00
DNP DS40 / Citizen CX
DNP DS80 / Citizen CX-W
2019-05-18 21:16:04 -04:00
DNP DS80DX
DNP DS-RX1 / DS-RX1HS / Citizen CY / CY-02
DNP DS620 / DS620A / Citizen CX-02
DNP DS820 / DS820A / Citizen CX-02W
DNP QW410 / Citizen CZ-01
2019-05-16 10:36:00 -04:00
Fujifilm ASK-300
HiTi P520L
HiTi P525L
2013-07-18 21:23:34 -04:00
Kodak Professional 1400
Kodak 305 Photo Printer
2013-11-20 21:35:17 -05:00
Kodak 605 Photo Printer
2013-07-18 21:23:34 -04:00
Kodak 805 Photo Printer
Kodak 6800 Photo Printer
2013-07-26 21:36:24 -04:00
Kodak 6850 Photo Printer
Kodak 7000 Photo Printer
Kodak 8810 Photo Printer
2019-05-16 10:36:00 -04:00
Magicard Tango 2E
2016-12-13 22:54:26 -05:00
Mitsubishi CP-3800DW
2015-01-10 17:43:12 -05:00
Mitsubishi CP-9550D/DW/DW-S/DZ/DZ-S
2016-10-23 17:43:13 -04:00
Mitsubishi CP-9600D/DW
Mitsubishi CP-D70DW and CP-D707DW
Mitsubishi CP-D70DW-S and CP-D707DW-S
2016-11-17 12:16:10 -05:00
Mitsubishi CP-D80DW
Mitsubishi CP-D90DW
Mitsubishi CP-K60DW-S
Mitsubishi CP-M1A / CP-M1E
Mitsubishi P95DW
Mitsubishi P93DW
Shinko CHC-S1245 (aka Sinfonia E1 and DNP Q8)
2019-05-16 10:36:00 -04:00
Shinko CHC-S2145 (aka Sinfonia S2)
Shinko CHC-S6145 (aka Sinfonia CS2)
Sony UP-CR10L (aka DNP DS-SL10)
2020-01-23 18:29:00 -05:00
Sony UP-DR80MD
2019-05-16 10:36:00 -04:00
Sony UP-DR150
Sony UP-DR200
Sony UP-D895
Sony UP-D897
Sony UP-D898 series
Stryker SDP1000
2013-12-14 20:55:37 -05:00
2015-01-05 21:39:22 -05:00
Work-in-progress Printers:
2013-12-14 20:55:37 -05:00
DNP M4 / Q4
DNP M8
HiTi P110 series
HiTi P510 series
HiTi M610 (not X610!)
HiTi P720L
HiTi P750L
2016-12-13 22:54:26 -05:00
HiTi P910L
HiTi CS-200e
HiTi CS-220e
2016-12-13 22:54:26 -05:00
ICI Imagedata OP900
2019-05-16 10:36:00 -04:00
Kodak 6900
Kodak 7010 / 7015
2019-05-16 10:36:00 -04:00
Magicard Rio 2E (and other Magicard models)
Mitsubishi CP30DW
Mitsubishi CP3020D/DE and CP3020DA/DAE
Mitsubishi CP9000DW, CP9500DW, and CP9600DW-S
Mitsubishi CP9800DW, CP9800DW-S, CP9810DW, and CP9820DW-S
Mitsubishi CP-M15
Olmec OP900
2019-05-16 10:36:00 -04:00
Shinko CHC-S2245 (aka Sinfonia S3)
Shinko CHC-S6145-5A (aka Sinfonia CS2-c)
2014-10-19 23:38:23 -04:00
Shinko CHC-S6245 (aka Sinfonia CE1)
2019-04-19 10:21:41 -04:00
Sony UP-CR20L (aka DNP DS-SL20)
2020-01-23 18:29:00 -05:00
Sony UP-DR80
***************************************************************************
This intelligent backend is needed to utilize many common dye-sublimation
photo printers under Linux, OSX, and other UNIX-like operating systems.
2020-10-26 10:08:54 -04:00
Although these printers advertise themselves as standard USB Printer
Class devices, they do not actually obey those specifications and
require special two-way handshaking in order to successfully print.
2014-01-17 21:24:18 -05:00
2020-10-26 10:08:54 -04:00
This backend only handles the low-level communication with these
printers; it is not able to "render" arbitrary image data into a
format these printers will accept, along with associated printing
parameters/options.
2017-04-21 07:04:01 -04:00
2020-10-26 10:08:54 -04:00
Consequently, this backend can only be used in conjunction with
Gutenprint (http://gimp-print.sf.net), version 5.2.10 or newer. Code
snapshots of this backend are bundled with Gutenprint, although this
repository is the canonical upstream source and is developed
independently.
2017-04-21 07:04:01 -04:00
2018-05-17 19:32:12 -04:00
As such, when compared to any given Gutenprint release, the code found
2020-10-26 10:08:54 -04:00
here has additional features, device support, and bugfixes. At the
same time, it may have half-developed features that don't quite work,
with giant bugs that come out at midnight to eat your cat.
So, while it is safe to use code in this repository with an older
Gutenprint release, supporting for newer models or printing options
that affect image rendering willl likely requires up-to-date
Gutenprint code,
Most printer support in selphy_print (and Gutenprint) was developed
without any assistance from the printer manufactuers, relying on
reverse-engineering and a great deal of experimentation.
On that note, please keep in mind that this software distributed
in the hope that it will be useful, but WITHOUT ANY WARRANTY WHATSOEVER.
***************************************************************************
2018-05-17 19:32:12 -04:00
This backend also supports a "standalone" mode that performs various
2019-05-16 10:36:00 -04:00
utility functions for most models, such as querying status and
configuring parameters. The exact commands supported for each
printer are documented below.
***************************************************************************
2013-06-30 12:48:46 -04:00
Compilation:
2018-05-17 19:32:12 -04:00
This tool requires libusb 1.0 to build. We highly recommend
2014-03-11 11:10:22 -04:00
v1.0.16 or newer due to general stability improvements. Versions
2018-05-17 19:32:12 -04:00
older than 1.0.10 will require -DLIBUSB_PRE_1_0_10 to be defined
2014-03-11 11:10:22 -04:00
(see the Makefile).
To further complicate things, libusb-1.0 had a temporary fork called
2018-05-17 19:32:12 -04:00
libusbx, but that was merged back into libusb as of v1.0.18.
Consequently, your distribution package for libusb-1.0 may be
2014-03-11 11:10:22 -04:00
called libusbx instead.
2017-11-09 19:16:05 -05:00
Additionally, you will need the CUPS development packages installed,
so we can figure out how the local CUPS instance is configured.
2016-11-17 10:23:15 -05:00
2019-05-16 10:36:00 -04:00
Lastly, in order to integrate the backend into an existing Gutenprint
installation you will need to install the Gutenprint development
headers.
2013-06-30 12:48:46 -04:00
Fedora/RedHat:
yum install libusb1-devel cups-devel gutenprint-devel
2013-06-30 12:48:46 -04:00
Debian/Ubuntu
apt-get install libusb-1.0-0-dev libcups2-dev libgutenprint-dev
All you need to do after that is type 'make'
Compilation for Windows:
This is highly experimental.
Currently only MinGW is supported. You will need the 'libltdl' and
'libusbx' MinGW packages.
Once the necessary packages are installed, run 'mingw64-make' and
everything should compile cleanly.
Please note that actually running this under Windows will require
use/installation of a generic USB driver such as WINUSB. For more
information, see:
http://zadig.akeo.ie
Another note. If you are using a NEC/Renesas USB 3.0 host
controller, you will need to ensure that it is using up-to-date
drivers or no devices will enumerate. For more information, see:
https://github.com/libusb/libusb/wiki/Windows
***************************************************************************
2013-06-30 12:48:46 -04:00
CUPS backend usage:
2013-07-18 21:23:34 -04:00
DEVICE_URI=someuri \
gutenprint52+usb job-id user title num-copies options [ filename ]
2013-07-18 21:23:34 -04:00
The backend generates output for CUPS to parse, including logging
2020-01-23 18:29:00 -05:00
print counts, reporting loaded media types, and remaining media counts.
2017-04-21 07:04:01 -04:00
Please note that this backend merely handles the low-level
communication with the printer! Actually generating print jobs requires
use of Gutenprint compiled with support for CUPS.
2017-04-21 07:04:01 -04:00
DEVICE_URI=someuri FINAL_CONTENT_TYPE=application/vnd.cups-command \
gutenprint52+usb job-id user title num-copies options [ filename ]
This parses a CUPS command file and performs actions listed in the file.
Implemented commands:
ReportLevels Report the marker (ie media) type and levels.
2019-05-16 10:36:00 -04:00
Other commands may be implemented in the future. Individual printer
models may not implement these commands.
Other Notes:
'someuri' is the URI returned by the backend when it probes for supported
devices. is invoked by calling the backend with no arguments.
The backend supports multiple URI schemes. First, the "modern" one:
gutenprint53+usb://backendname/serialnum
And the old/legacy/classic ones:
gutenprint52+usb://manufacturer/model/?backend=backendname&serial=serialnum
gutenprint52+usb://manufacturer/model/?serial=serialnum&backend=backendname
The URI scheme generated at device probing depends on the version of
gutenprint installed. By default, the modern scheme is used when compiled
against Gutenprint 5.3 or newer, and the legacy scheme is used with
Gutenprint 5.2.
Regardless of the scheme generated at probe time, the backend will continue
to detect and parse both schemes indefinitely as to not break backwards
compatibility with existing deployments. To manually switch the URI
scheme type generated at runtime, set the OLD_URI_SCHEME environment
variable to either 0 or 1, as appropriate.
***************************************************************************
2013-06-30 12:48:46 -04:00
Standalone usage:
2013-07-18 21:23:34 -04:00
This backend is set up as a multi-call executable; that is to say
behaivor changes based on the name used to invoke the executable.
When compiled, a set of symlinks are created, corresponding to the generic
name of each of the internal backends. Alternatively you may set
the BACKEND environment variable to force a specific backend to be used.
These commands are equivalent:
BACKEND=backend ./gutenprint52+usb [ arguments ]
./backend [ arguments ]
The 'backend' name is any one of the names listed when invoking the
executable with no arguments. For example:
./dnpds40
DEBUG: Multi-Call Dye-sublimation CUPS Backend version 0.88
[ ... ]
DEBUG: Standalone DNP DS-series / Citizen C-series backend version 0.106
DEBUG: supporting: dnp_citizen dnpds40 dnpds80 dnpds80dx dnpds620 dnpds820 dnprx1 citizencw01 citizencw02 citizencx02
[ ... ]
The first entry after 'supporting' is the generic backend name, while
the others correspond to specific models the backend supports. Any one
can be used as the 'backend' name.
2013-07-18 21:23:34 -04:00
All backends support the following invocations:
2013-07-18 21:23:34 -04:00
backend [ arguments ]
2015-11-19 08:26:15 -05:00
backend [ arguments ] filename
backend [ arguments ] - < filename
somecommand | backend [ arguments ] -
2013-07-18 21:23:34 -04:00
The 'filename' here refers to the raw spool data generated by
2018-05-17 19:32:12 -04:00
Gutenprint (eg via its gimp plugin) or the Windows print-to-file
2013-07-18 21:23:34 -04:00
output.
2013-06-30 12:48:46 -04:00
All global arguments:
2015-11-19 08:26:15 -05:00
-D Increment debug level [1]
-G Display GPL text
-f Enable fast return mode if possible [2]
-d numcopies Print 'numcopies' of the supplied job
-v Silence all output except for warnings/errors
[1] This argument can be repeated to increase the debug level.
Alternatively, the 'DYESUB_DEBUG' environment variable can be
2015-11-19 08:26:15 -05:00
used. For example, '-DDD' and 'DYESUB_DEBUG=3' are equivalent.
DYESUB_DEBUG=1 Enable debug output
DYESUB_DEBUG=2 Dump contents of short messges
DYESUB_DEBUG=3 Dump contents of all messages
[2] This terminates the backend as soon as the printer has
2019-05-16 10:36:00 -04:00
accepted the print job, without waiting for the print job
2018-05-17 19:32:12 -04:00
to complete. Not all printers support this feature. This
can also be enabled by setting the 'FAST_RETURN' environment
variable. This is the default behavior when using this backend
2018-05-17 19:32:12 -04:00
with CUPS.
Finally, some backends support additional arguments; see their details
below.
***************************************************************************
Other Environment Variables:
If you have multiple models of the same printer family connected
simultaneously, the backend will choose the first one it finds.
If you wish to target a specific device, you may specify its
serial number using the 'SERIAL' environment variable. For example:
SERIAL=N782 backend filename [ arguments ]
All backends support an additional operational mode, to test out
unknown models. To use this mode, specify the VID, PID and its
internal device type as environment variables:
EXTRA_VID=04a9 EXTRA_PID=3ab1 EXTRA_TYPE=7 backend filename
2018-05-17 19:32:12 -04:00
The VID and PID are specified in hexidecimal, and the TYPE is
the P_XXX enumeration defined in backend_common.h. The '7' in this
example corresponds to most Canon SELPHY CP models, and is what you
would use if you were trying to get the backend to detect an
otherwise unrecognized SELPHY CP model.
If you are able to successfuly print using this technique,
please let us know so we can add the apppriate entry to the
internal database.
For debugging USB operation, there following environment variables
can be set:
MAX_XFER_SIZE Maximum transfer size, in bytes.
XFER_TIMEOUT Timeout, in milliseconds, for all USB operations
for example:
MAX_XFER_SIZE=32768 XFER_TIMEOUT=30000 backend filename
To change the location of backend data at runtime, set CORRTABLE_PATH
to the appropriate directory.
Finally, BACKEND_QUIET can be set to a non-zero value to silence all
output other than warnings and errors.
***************************************************************************
Standalone status queries:
If you just want to query the printer and media status in a
printer-independent manner, the backend supports reporting a standard
set of data in either textual or JSON format. This is used with the
BACKEND_STATS_ONLY environment variable:
BACKEND_STATS_ONLY=? BACKEND=backend [SERIAL=??] ./gutenprint53+usb
BACKEND_STATS_ONLY=? [SERIAL=??] ./backend
BACKEND_STATS_ONLY=1 will report in textual format, for example:
Backend: HiTi Photo Printers
Version: 0.100 / 0.16
Timestamp: 2019-1 2-13 14:54:28
Manufacturer: HiTi
Model: HiTi:Usb Photo Printer:HiTi P520L
Serial Number: 2WC4A1013968279
Firmware Version: 1.21.0.i
Printer Status: Idle
Lifetime Prints: 194
Media 0 Type: 4x6
Media 0 Level: 313 / 500
BACKEND_STATS_ONLY=2 will report in JSON format, for example:
{
"backend": "HiTi Photo Printers",
"version": "0.100 / 0.16",
"timestamp": "2019-12-13 14:57:38",
"manufacturer": "HiTi",
"model": "HiTi:Usb Photo Printer:HiTi P520L",
"serial": "2WC4A1013968279",
"firmware": "1.21.0.i",
"status": "Idle",
"counters": {
"lifetime": 194
},
"media": [
{
"type": "4x6",
"level": "OK",
"levelnow": 313,
"levelmax": 500
}
]
}
***************************************************************************
2013-07-18 21:23:34 -04:00
BACKEND=canonselphy
2013-06-30 12:48:46 -04:00
2019-05-16 10:36:00 -04:00
Model IDs recognized:
canon-cp10 canon-cp100 canon-cp200 canon-cp220 canon-cp300 canon-cp330
canon-cp400 canon-cp500 canon-cp510 canon-cp520 canon-cp530 canon-cp600
canon-cp710 canon-cp720 canon-cp730 canon-cp740 canon-cp750 canon-cp760
canon-cp770 canon-cp780 canon-cp790 canon-cp800 canon-cp810 canon-cp900
2019-05-16 10:36:00 -04:00
canon-es1 canon-es2 canon-es20 canon-es3 canon-es30 canon-es40
Model IDs for backwards compatibility with older releases:
selphycp10 selphycp100 selphycp200 selphycp220 selphycp300 selphycp330
selphycp400 selphycp500 selphycp510 selphycp520 selphycp530 selphycp600
selphycp710 selphycp720 selphycp730 selphycp740 selphycp750 selphycp760
selphycp770 selphycp780 selphycp790 selphycp800 selphycp810 selphycp900
selphyes1 selphyes2 selphyes20 selphyes3 selphyes30 selphyes40
2013-06-30 12:48:46 -04:00
Verified supported printers:
2018-05-17 19:32:12 -04:00
ES1, ES2, ES3, ES30, ES40, CP-10, CP-100, CP-200, CP-300, CP-330,
CP400, CP500, CP510, CP710, CP720, CP730, CP740, CP750, CP760, CP770,
CP780, CP790, CP800, CP900
2013-06-30 12:48:46 -04:00
Unverified/untested, but should work: (let us know, please!)
2013-06-30 12:48:46 -04:00
2014-05-18 18:31:32 -04:00
ES20, CP-220, CP520, CP530, CP600, CP810
2014-05-05 12:49:41 -04:00
Valid commands:
2018-05-17 19:32:12 -04:00
-R Reset printer to factory defaults
-s Query printer status
2019-05-16 10:36:00 -04:00
Notes:
2020-01-23 18:29:00 -05:00
* The SELPHY ES3 and ES30 cannot report the loaded media type
2019-05-16 10:36:00 -04:00
* All models can report media empty, but not quantity remaining
2018-05-17 19:32:12 -04:00
***************************************************************************
BACKEND=canonselphyneo
2019-05-16 10:36:00 -04:00
Model IDs recognized:
canon-cp820 canon-cp910 canon-cp1000 canon-cp1200 canon-cp1300
2019-05-16 10:36:00 -04:00
Model IDs for backwards compatibility with older releases:
selphycp820 selphycp910 selphycp1000 selphycp1200 selphycp1300
Verified supported printers:
2018-05-17 19:32:12 -04:00
2019-05-16 10:36:00 -04:00
CP1000, CP1200, CP1300
Untested, but expected to work:
2019-05-16 10:36:00 -04:00
CP820, CP910
Valid commands:
2018-05-17 19:32:12 -04:00
-R Reset printer to factory defaults
-s Query printer status
2019-05-16 10:36:00 -04:00
Notes:
* All models can report media empty, but not quantity remaining
2018-05-17 19:32:12 -04:00
***************************************************************************
2013-07-18 21:23:34 -04:00
BACKEND=kodak1400
Additional model IDs recognized:
2019-05-16 10:36:00 -04:00
kodak-1400 kodak-805
mitsubishi-3020d mitsubishi-3020da, mitsubishi-3020dae mitsubishi-3020de
mitsubishi-3020du
2019-05-16 10:36:00 -04:00
Model IDs for backwards compatibility with older releases:
kodak1400 kodak805 mitsu3020d mitsu3020da
2013-07-18 21:23:34 -04:00
Verified supported printers:
2013-06-30 12:48:46 -04:00
2013-07-18 21:23:34 -04:00
Kodak 1400
Kodak 805
2013-06-30 12:48:46 -04:00
Work-in-progress printers:
Mitsubishi CP3020D/DE
Mitsubishi CP3020DA/DAE
Valid commands:
-C filename Set tone curve [1]
Notes:
2020-01-23 18:29:00 -05:00
* These models cannot report media type or remaining levels,
but are able to report out of media conditions.
2019-05-16 10:36:00 -04:00
[1] Format of curvedata file:
2019-05-16 10:36:00 -04:00
256 entries each of Yellow, Magenta, Cyan mappings:
Values are unsigned 16-bit big endian, between 0 and ???
(unsure as to the bit usage)
2018-05-17 19:32:12 -04:00
***************************************************************************
BACKEND=kodak68x0
2019-05-16 10:36:00 -04:00
Model IDs recognized:
2019-05-16 10:36:00 -04:00
kodak-6800 kodak-6850
Model IDs for backwards compatibility with older releases:
kodak6800 kodak6850
2013-06-30 12:48:46 -04:00
2013-07-18 21:23:34 -04:00
Verified supported printers:
Kodak 6800
Kodak 6850
Development was sponsored in part by:
LiveLink Technology [ www.livelinktechnology.net ]
Valid commands:
-c filename Query tone curve [1]
-C filename Set tone curve [1]
-l filename Query Current tone curve from RAM [1]
-L filename Store Current tone curve in RAM [1]
2019-05-16 10:36:00 -04:00
-m Query media information
-s Query printer status
2018-05-17 19:32:12 -04:00
-R Reset printer to factory defaults
-X id Cancel print job 'id' [2]
Notes:
2019-05-16 10:36:00 -04:00
[1] Format of curvedata file:
2019-05-16 10:36:00 -04:00
256 entries each of Yellow, Magenta, Cyan mappings:
Values are unsigned 16-bit big endian, between 0 and 16383
(ie 14-bit)
2019-05-16 10:36:00 -04:00
[2] Job ID is the Internal Job ID (reported via status)
This cancels a multi-copy print job.
To see which jobs are active/pending, see the output of the
'-s' command, specifically the 'Bank' output.
2018-05-17 19:32:12 -04:00
***************************************************************************
2013-11-20 21:35:17 -05:00
BACKEND=kodak605
Additional model IDs recognized:
kodak-605, kodak-7000, kodak-7010, kodak-7015,
2013-11-24 11:01:44 -05:00
Verified supported printers:
2013-11-20 21:35:17 -05:00
Kodak 605
Kodak 7000
2013-11-20 21:35:17 -05:00
Work-in-progress printers:
Kodak 7010/7015
Valid commands:
-b [ 0 | 1 ] Disable or Enable the printer control panel
-c filename Query User tone curve from flash [1]
-C filename Store User tone curve in flash [1]
-e Query error log
-F Flash printer LEDs for 5 seconds
-i Query printer firmware information
-l filename Query Current tone curve from RAM [1]
-L filename Store Current tone curve in RAM [1]
2019-05-16 10:36:00 -04:00
-m Query media information
-r Reset User tone curve to default [3]
-R Reset printer to factory defaults
-s Query printer status
-X id Cancel print job 'id' [2]
2013-11-24 11:01:44 -05:00
Notes:
2019-05-16 10:36:00 -04:00
[1] Format of curvedata file:
2013-11-24 11:01:44 -05:00
2019-05-16 10:36:00 -04:00
256 entries each of Yellow, Magenta, Cyan mappings:
Values are unsigned 16-bit big endian, between 0 and ???
(unsure as to the bit usage)
2013-11-20 21:35:17 -05:00
2019-05-16 10:36:00 -04:00
[2] Job ID is the Internal Job ID (reported via status)
This cancels a multi-copy print job.
To see which jobs are active/pending, see the output of the
'-s' command, specifically the 'Bank' output.
[3] Default printer tone curve is a linear 'val << 3'
2018-05-17 19:32:12 -04:00
***************************************************************************
2013-07-18 21:23:34 -04:00
BACKEND=shinkos2145
2019-05-16 10:36:00 -04:00
Model IDs recognized:
shinko-chcs2145 sinfonia-chcs2145
2013-07-18 21:23:34 -04:00
Verified supported printers:
Shinko CHC-S2145 (aka "Sinfonia S2")
Development was sponsored in part by:
LiveLink Technology [ www.livelinktechnology.net ]
In order to use this backend, you will need to ensure the printer is
2018-05-17 19:32:12 -04:00
configured to use the 'DRV' (as opposed to 'DLL') operating mode. See
the printer documentation for details on how to set this.
Valid commands:
-b [ 0 | 1 ] Disable or Enable the printer control panel
-c filename Query User tone curve from flash [1]
-C filename Store User tone curve in flash [1]
-e Query Error log
-F Flash printer LEDs for 5 seconds
-i Query printer firmware information
-l filename Query Current tone curve from RAM [1]
-L filename Store Current tone curve in RAM [1]
-m Query media information
-r Reset User tone curve to default [4]
-R Reset printer to factory defaults
-s Query printer status
-u Query user string
-U somestring Set user string to 'somestring'
-X id Cancel print job 'id' [3]
Notes:
2019-05-16 10:36:00 -04:00
[1] Format of curvedata file:
2019-05-16 10:36:00 -04:00
256 entries each of Yellow, Magenta, Cyan mappings:
Values are unsigned 16-bit big endian, between 0 and 2047
(ie only 11 bits used)
2019-05-16 10:36:00 -04:00
[3] Job ID is the Internal Job ID (reported via status)
This cancels a multi-copy print job.
To see which jobs are active/pending, see the output of the
'-s' command, specifically the 'Bank' output.
2019-05-16 10:36:00 -04:00
[4] Default printer tone curve is a linear 'val << 3'
2018-05-17 19:32:12 -04:00
***************************************************************************
BACKEND=shinkos1245
Low-level documentation was provided by Sinfonia, Inc. Thank you!
2019-05-16 10:36:00 -04:00
Model IDs recognized:
shinko-chcs1245 sinfonia-chcs1245
2018-01-09 21:37:41 -05:00
Verified supported printers:
Shinko CHC-S1245 (aka "Sinfonia E1")
Unsupported printers (unknown VID/PID)
DNP Q8
2015-02-08 18:59:26 -05:00
Valid commands:
-s Query printer status
-m Query media information
-u Query user string
-U somestring Set user string to 'somestring'
-X id Cancel print job 'id' [1]
2018-05-17 19:32:12 -04:00
-R Reset printer to factory defaults
2015-02-18 20:54:57 -05:00
-F Tone curve commands affect FINE table
-c filename Query User tone curve from flash [2]
-C filename Store User tone curve in flash [2]
-l filename Query Current tone curve from RAM [2]
-L filename Store Current tone curve in RAM [2]
2020-01-23 18:29:00 -05:00
Notes:
2019-05-16 10:36:00 -04:00
[1] Job ID is the Internal Job ID (reported via status)
This cancels a multi-copy print job.
To see which jobs are active/pending, see the output of the
'-s' command, specifically the 'Bank' output.
2015-02-18 20:54:57 -05:00
2019-05-16 10:36:00 -04:00
[2] Format of tone curve file:
2015-02-18 20:54:57 -05:00
2019-05-16 10:36:00 -04:00
256 entries each of Yellow, Magenta, Cyan mappings:
Values are unsigned 16-bit big endian, between 0 and 16383
(ie only 14 bits used)
2015-02-18 20:54:57 -05:00
2019-05-16 10:36:00 -04:00
***************************************************************************
BACKEND=shinkos6145
2019-05-16 10:36:00 -04:00
Low-level documentation was provided by Sinfonia and CIAAT. Thank you!
2019-05-16 10:36:00 -04:00
Model IDs recognized:
sinfonia-chcs6145 ciaat-brava-21 shinko-chcs6145
2020-03-03 18:52:22 -05:00
sinfonia-chcs2245 hiti-m610 kodak-6900
2019-05-16 10:36:00 -04:00
Model IDs for backwards compatibility with older releases:
2019-05-16 10:36:00 -04:00
shinks6145 brava21
Verified supported printers:
2015-08-28 21:08:08 -04:00
Ciaat Brava 21
2016-12-13 22:54:26 -05:00
Shinko CHC-S6145 (aka "Sinfonia CS2")
2020-08-10 08:04:05 -04:00
Sinfonia CHC-S2245 (aka "S3")
Work-in-progress printers:
HiTi M610
2019-05-16 10:36:00 -04:00
Kodak 6900
2020-08-10 08:04:05 -04:00
Shinko CHC-S6145-5A (aka "CS2-c")
2019-05-16 10:36:00 -04:00
*** VERY IMPORTANT ***
In order to generate usable output, the Sinfonia CHC-S6145 and CHC-S2245
printers (and their siblings listed above) require the input data to be
transformed using specific image processing algorithms.
The library that implements this processing is dynamically loaded
at runtime. There are three options:
* libS6145ImageProcess and S2245IP -- Supported by Sinfonia, these
are proprietary libraries. They can be obtained by politely
contacting your local Sinfonia distributor.
If you have the appropriate permission fron Sinfonia and their
technical and legal limitations are acceptible to you, we
recommend you use these official supported libraries.
* libS6145ImageReProcess and libS2245ImageReProocess -- GPL'd
re-implementations of the Sinfonia algorithms, available as
source. They are drop-in replacement that appears to generate
identical output to the proprietary Sinfonia libraries.
DISCLAIMER: Sinfonia Inc was not involved in the creation of
these libraries and is not responsible in any way for any
deficiencies in its output. They will provide no support if it is
used.
Do *NOT* contact Sinfonia for support if you are using
libS6146ImageReProcess or libS2245ImageReProcess!
(Please see the full disclaimer in libS6145ImageReProcess.c and
libS2245ImageReProcess.c)
As selphy_print is released under the terms of the GPL, it cannot
normally be combined with proprietary libraries.
Therefore, the authors of selphy_print grant its users an
additional permission (under section 7 of the GPLv3) to combine
and/or redistribute it with the proprietart libS6145ImageProcess
and/or S2245IP libraries. For the full text of this license
exception, please see the header of backend_shinkos6145.c
Valid commands:
-c filename Query User tone curve from flash [1]
-C filename Store User tone curve in flash [1]
-e Query Error log
-F Flash printer LEDs for 5 seconds
-i Query printer firmware information
-k num Specify standby delay (5-240 minutes)
-l filename Query Current tone curve from RAM [1]
-L filename Store Current tone curve in RAM [1]
-m Query media information
2019-05-16 10:36:00 -04:00
-q filename Dump eeprom data [4]
-Q filename Dump image correction data [4]
-r Reset User tone curve to default [3]
-R Reset printer to factory defaults
-s Query printer status
-X id Cancel print job 'id' [2]
Notes:
2019-05-16 10:36:00 -04:00
[1] Format of curvedata file:
2019-05-16 10:36:00 -04:00
256 entries each of Yellow, Magenta, Cyan mappings:
Values are unsigned 16-bit big endian, between 0 and 2047
(ie only 11 bits used)
2019-05-16 10:36:00 -04:00
[2] Job ID is the Internal Job ID (reported via status)
This cancels a multi-copy print job.
To see which jobs are active/pending, see the output of the
'-s' command, specifically the 'Bank' output.
2019-05-16 10:36:00 -04:00
[3] Default printer tone curve is a linear 'val << 3'
2019-05-16 10:36:00 -04:00
[4] This is used as an input to the image processing code, and is
only useful for debugging purposes.
2019-05-16 10:36:00 -04:00
***************************************************************************
BACKEND=shinkos6245
Low-level documentation was provided by Sinfonia, Inc. Thank you!
2019-05-16 10:36:00 -04:00
Model IDs recognized:
sinfonia-chcs6245 hiti-p910l shinko-chcs6245
kodak-8810
2019-05-16 10:36:00 -04:00
Model IDs for backwards compatibility with older releases:
2019-05-16 10:36:00 -04:00
shinkos6245 hitip910
Verified supported printers:
Kodak 8810
Work-in-process printers:
HiTi P910L
Shinko CHC-S6245 (aka "Sinfonia CE1")
Valid commands:
-b [ 0 | 1 ] Disable or Enable the printer control panel [4]
-c filename Query User tone curve from flash [1]
-C filename Store User tone curve in flash [1]
-e Query Error log
-F Flash printer LEDs for 5 seconds
-i Query printer firmware information
-k num Specify standby delay (5-240 minutes)
-l filename Query Current tone curve from RAM [1]
-L filename Store Current tone curve in RAM [1]
-m Query media information
-r Reset User tone curve to default [3]
-R Reset printer to factory defaults
-s Query printer status
-X id Cancel print job 'id' [2]
Notes:
2019-05-16 10:36:00 -04:00
[1] Format of curvedata file:
2019-05-16 10:36:00 -04:00
256 entries each of Yellow, Magenta, Cyan mappings:
Values are unsigned 16-bit big endian, between 0 and 2047
(ie only 11 bits used)
2019-05-16 10:36:00 -04:00
[2] Job ID is the Internal Job ID (reported via status)
This cancels a multi-copy print job.
To see which jobs are active/pending, see the output of the
'-s' command, specifically the 'Bank' output.
[3] Default printer tone curve is a linear 'val << 3'
2020-01-23 18:29:00 -05:00
[4] Kodak 8810 only
2018-05-17 19:32:12 -04:00
***************************************************************************
BACKEND=sonyupd
2013-07-18 21:23:34 -04:00
Additional model IDs recognized:
sony-updr150 sony-updr200 sony-upcr10l
2019-04-20 19:55:36 -04:00
sony-upd895 sony-upd897 dnp-sl10
2019-05-16 10:36:00 -04:00
Model IDs for backwards compatibility with older releases:
sonyupdr150 sonyupdr200 sonyupcr10
2013-07-18 21:23:34 -04:00
Verified supported printers:
2019-05-16 10:36:00 -04:00
Sony UP-CR10L
Sony UP-D895
Sony UP-D897
2019-05-16 10:36:00 -04:00
Sony UP-DR150
Sony UP-DR200
Unverified/untested, but should work:
2018-05-17 19:32:12 -04:00
2019-04-06 17:33:19 -04:00
DNP DS-SL10
2014-05-08 09:58:27 -04:00
2019-04-06 17:33:19 -04:00
Valid commands:
-s Query printer status
2019-05-16 10:36:00 -04:00
Notes:
2020-01-23 18:29:00 -05:00
* These models cannot report media type or remaining levels,
but are able to report out of media conditions.
2019-04-20 19:55:36 -04:00
***************************************************************************
BACKEND=sonyupdneo
2019-05-16 10:36:00 -04:00
Model IDs recognized:
sony-upcr20l sony-upd898 sony-updr80 sony-updr80md dnp-sl20
2020-01-23 18:29:00 -05:00
Verified supported printers:
Sony UP-DR80MD
Stryker SDP1000
Sony UP-D898 / UP-X898
2020-01-23 18:29:00 -05:00
Work-in-progress printers
Sony UP-DR80
2019-04-20 19:55:36 -04:00
Work-in-progress printers (Lack USB PIDs)
Sony UP-CR20L
DNP DS-SL20
Valid commands:
2019-05-16 10:36:00 -04:00
-s Query printer status
2019-04-20 19:55:36 -04:00
2020-01-23 18:29:00 -05:00
Notes:
* The UP-D89x series is unable to report media type or levels, but
can report media empty conditions.
2018-05-17 19:32:12 -04:00
***************************************************************************
BACKEND=mitsu70x
2019-05-16 10:36:00 -04:00
Model IDs recognized:
mitsubishi-d70dw mitsubishi-d80dw mitsubishi-k60dw
fujifilm-ask-300 mitsubishi-d707dw mitsubishi-k60dws
2019-05-16 10:36:00 -04:00
Model IDs for backwards compatibility with older releases:
kodak-305 mitsud80 mitsuk60 kodak305 fujiask300
Supported and tested printers:
2019-05-16 10:36:00 -04:00
Fujifilm ASK-300
Kodak 305
2016-11-17 15:27:44 -05:00
Mitsubishi CP-D70DW
Mitsubishi CP-D70DW-S
2019-05-16 10:36:00 -04:00
Mitsubishi CP-D707DW
Mitsubishi CP-D707DW-S
2016-11-17 12:16:10 -05:00
Mitsubishi CP-D80DW
2016-12-13 22:54:26 -05:00
Mitsubishi CP-K60DW-S
Unsupported printers (Unknown VID/PID):
Mitsubishi CP-D80DW-S
Development was sponsored in part by:
Schreiber & Freunde GmbH & Co. KG
A generous benefactor who wishes to remain anonymous
*** VERY IMPORTANT ***
In order to generate usable output, this family of printers require
the input data to be transformed using specific image processing
algorithms.
The library that implements this processing is dynamically loaded
at runtime. There is currently only one option:
* libMitsuD70ImageReProcess -- GPL'd re-implementation of the
Mitsubishi algorithms, available as source. No guaranteees are
2020-01-05 11:43:00 -05:00
made about its output quality versus Mitsubishi's
proprietary drivers, but is generally considerd quite good.
DISCLAIMER: Mitsubishi was not involved in the creation of
libMitsuD70ImageReProcess and is not responsible in any way for
any deficiencies in its output. They will provide no support if
it is used.
Do *NOT* contact Mitsubishi for support if you are using
2019-05-16 10:36:00 -04:00
any combination of gutenprint, selphy_print or libMitsuD70ImageReProcess.
(Please see the full disclaimer in libMitsuD70ImageReProcess.c)
Valid commands:
-j Query Job status
-k num Specify standby delay (1-60 minutes, 0 disables)
-s Query printer status
-w Wake up printer
2017-12-15 14:06:00 -05:00
-W Wake up printer (and wait)
-x num Set USB iSerialNumber reporting (1 yes, 0 no) [1]
-X id Cancel print job 'id' [2]
[1] Printer will need to be power-cycled for this to take effect.
[2] Job ID is the Internal Job ID (reported via job status query)
***************************************************************************
BACKEND=mitsud90
2019-05-16 10:36:00 -04:00
Model IDs recognized:
mitsubishi-d90dw
Supported and tested printers:
Mitsubishi CP-D90DW
Mitsubishi CP-M1A / CP-M1E
Work-in-progress printers:
Mitsubishi CP-M15E
*** VERY IMPORTANT ***
The CP-M1 family is similar to the CP-D70 family in that it requires
the input data to be gamma corrected (and transformed in other ways)
before it is sent to the printer.
2020-03-03 18:52:22 -05:00
Consideeable progress has been made, and the implementation is
considered feature-complete. In theory, the output quality should be
comparable to Mitsubishi's own drivers.
This code has been implemented in the lib70 driver, and note that while
feature complete, it has NOT been tested.
Mitsubishi was *NOT* involved in the creation of this library, and is
not responsible in any way for the library or any deficiencies in its
output. They will provide no support if it is used.
Valid commands:
-i Query printer information
-j jobid Query job status [1]
-k num Specify standby delay (1-255 minutes, 0 disables)
-m Query printer media
-s Query printer status
-x num Set USB iSerialNumber reporting (1 yes, 0 no) [2]
[1] Job ID is the Internal Job ID (reported via job status query)
[2] Printer will need to be power-cycled for this to take effect.
Only valid for CP-D90
2018-05-17 19:32:12 -04:00
***************************************************************************
BACKEND=mitsu9xxx
2019-05-16 10:36:00 -04:00
Model IDs recognized:
mitsubishi-9000dw mitsubishi-9500dw mitsubishi-9550dw mitsubishi-9550dw-s
mitsubishi-9600dw mitsubishi-9800dw mitsubishi-9800dw-s mitsubishi-9810dw
mitsubishi-9550d mitsubishi-9550dz mitsubishi-9800d mitsubishi-9800dz
2019-05-16 10:36:00 -04:00
mitsubishi-9810d
Model IDs for backwards compatibility with older releases:
mitsu9000 mitsu9500 mitsu9550 mitsu9600 mitsu9800 mitsu9810
2014-12-15 09:12:05 -05:00
2015-01-10 17:43:12 -05:00
Supported and tested printers:
Mitsubishi CP9550D/DW and CP9550DZ/DZS/DW-S
Mitsubishi CP9600D/DW
Mitsubishi CP9800DZ/DZS/DW-S [1]
2018-05-17 19:32:12 -04:00
Unverified/untested, but should work: (let us know, please!)
Mitsubishi CP9800D/DW [1]
Mitsubishi CP9810D/DW [1]
Mitsubishi CP9820DW-S [1]
2014-12-15 09:12:05 -05:00
Work-in-progress printers:
Mitsubishi CP9000D/DW
Mitsubishi CP9500D/DW
Mitsubishi CP30DW
Mitsubishi CP9600DW-S/DZ/DZ-S
2014-12-15 09:12:05 -05:00
Valid commands:
-s Query printer status
-m Query printer media
2018-04-20 16:17:47 -04:00
-X Cancel current job
2014-12-15 09:12:05 -05:00
Notes:
2017-03-23 00:38:51 -04:00
[1] **** VERY IMPORTANT ****
The CP-98xx family is similar to the CP-D70 family in that it requires
2020-02-11 15:49:13 -05:00
the input data to be gamma corrected (and transformed in other ways)
before it is sent to the printer.
Considerable progress has been made in decoding the CP-98xx data
tables and algorithms, and everything but sharpening has now been
implemented. In theory, the output quality should be comparable to
2020-02-11 15:49:13 -05:00
Mitsubishi's own drivers.
This code has been implemented in the lib70 driver, and note that while
feature complete, it has NOT been tested.
Mitsubishi was *NOT* involved in the creation of this library, and is
not responsible in any way for the library or any deficiencies in its
output. They will provide no support if it is used.
2018-05-17 19:32:12 -04:00
***************************************************************************
BACKEND=mitsup9x
2019-05-16 10:36:00 -04:00
Model IDs recognized:
mitsubishi-p95d mitsubishi-p93d
Model IDs for backwards compatibility with older releases:
2019-05-16 10:36:00 -04:00
mitsup95d mitsup93d
Development was sponsored by:
A benefactor who wishes to remain anonymous
Verified supported printers:
2018-05-17 19:32:12 -04:00
Mitsubishi P95DW
Mitsubishi P93DW
2018-01-08 07:20:47 -05:00
Valid commands:
2018-05-17 19:32:12 -04:00
2018-01-08 07:20:47 -05:00
-s Query printer status
2019-05-16 10:36:00 -04:00
Notes:
2020-01-23 18:29:00 -05:00
* These models cannot report media type or remaining levels,
but are able to report out of media conditions.
2018-05-17 19:32:12 -04:00
***************************************************************************
BACKEND=dnp_citizen
2019-05-16 10:36:00 -04:00
Model IDs recognized:
dnp-ds40 dnp-ds80 dnp-ds80dx dnp-ds620 dnp-ds820 dnp-dsrx1 dnp-ds620
dnp-qw410
citizen-cw-01 citizen-cw-02 citizen-cx-02 citizen-cx citizen-cx-w
citizen-cy citizen-cy-02 citizen-op900 citizen-op900ii citicen-cx-02w
citizen-cz-01
2019-05-16 10:36:00 -04:00
Model IDs for backwards compatibility with older releases:
dnpds40 dnpds90 dnpds80dx dnpds620 dnpds820 dnpdsrx1
citizencw01 citizencw02 citizencx02
Verified supported printers:
2016-12-13 22:54:26 -05:00
DNP DS40 (aka Citizen CX)
DNP DS80 (aka Citizen CX-W)
2019-05-18 21:16:04 -04:00
DNP DS80DX
DNP DS620 / DS620A (aka Citizen CX-02)
DNP DS820 / DS820A (aka Citizen CX-02W)
DNP DS-RX1 / DNP DS-RX1HS (aka Citizen CY and CY-02)
DNP DS-QW410
Theoretically supported printers: (Untested)
Citizen CW-01 / OP900
Citizen CW-02 / OP900II
Citizen CX-02
Citizen CZ-01
2016-12-13 22:54:26 -05:00
Mitsubishi CP-3800DW
Work-in-progress printers: (USB PIDs unknown)
DNP M4 / Q4
Olmec OP900
ICI Imagedata OP900
Development was sponsored in part by:
Marco Di Antonio
LiveLink Technology [ www.livelinktechnology.net ]
2020-01-05 11:43:00 -05:00
Multiple generous benefactors who whish to remain anonymous
This backend supports additional commands:
-i Query printer information (resolution, etc)
-I Query printer sensor information
-n Query printer counters
-N [ A | B | M ] Reset Counter A/B/M [2]
2015-08-28 21:08:08 -04:00
-p num Set 'P' counter to 'num' [2]
-s Query printer status
-k num Specify standby delay (1-99 minutes, 0 disables) [1]
-K num Keep Media Status Across Power Cycles (1 yes, 0 no) [4]
-x num Set USB iSerialNumber reporting (1 yes, 0 no) [3]
-X Cancel current job
-R Reset printer to defaults
Notes:
2017-03-23 00:38:51 -04:00
[1] Only supported by DS620 and DS820
2015-06-22 23:19:28 -04:00
[2] Certain printer features may require updating the printer firmware
[3] Only supported by RX1HS, DS620, DS820, and QW410
[4] Only supported by DS620, DS820, and QW410
2018-05-17 19:32:12 -04:00
***************************************************************************
BACKEND=magicard
2019-05-16 10:36:00 -04:00
Model IDs recognized:
magicard-tango-2e magicard-enduro magicard-enduroplus magicard-rio-2e
2019-05-16 10:36:00 -04:00
Model IDs for backwards compatibility with older releases:
tango2e enduro enduroplus
2017-11-23 07:13:03 -05:00
Verified supported printers:
Tango 2E
2017-11-23 07:13:03 -05:00
Work-in-progress printers:
Rio 2E
Tango +L
Enduro
Enduro+
(And all others)
This backend supports additional commands:
magicard [command [arg] ]
Valid commands:
-s Query printer status
-q Generate printer information dump
2017-11-23 14:26:52 -05:00
-I Query printer sensors
-T Print self-test card
-E Eject card in printer
-R Reset printer
2019-05-16 10:36:00 -04:00
Notes:
2020-01-23 18:29:00 -05:00
* These models cannot report media type or remaining levels,
but are able to report out of media conditions.
***************************************************************************
BACKEND=hiti
Model IDs recognized:
hiti-p520l hiti-p525l hiti-p52x
hiti-p720l hiti-p750l
Verified supported printers:
HiTi P520L
HiTi P525L
Theoretically supported printers (Untested)
HiTi P720L
HiTi P750L
Work-in-progress printers
HiTi P110 series
HiTi P510 series
This backend supports additional commands:
hiti [command [arg] ]
Valid commands:
-i Query printer information
-r Soft reset printer
-R Reset printer to factory defaults
-s Query printer status
2020-01-23 18:29:00 -05:00
Notes:
2020-01-23 18:29:00 -05:00
* Firmware v1.19-v1.21 for the P520L and P525L have a major issue
that results in bulk data transfers not functioning under Linux.
This problem also affected HiTi's semi-official Linux drivers, and
was finally fixed in v1.22.
***************************************************************************