mitsu70x: Better support for the CP-D707DW
We can now determine job status of upper vs lower deck. Need better smarts for determinig if we can print. (Testing provided by a contributor who wishes to remain anonymous!)
This commit is contained in:
parent
3589a09ed3
commit
4b13d56d9d
6
README
6
README
|
@ -48,7 +48,7 @@
|
|||
Mitsubishi CP-3800DW
|
||||
Mitsubishi CP-9550D/DW/DW-S/DZ/DZ-S
|
||||
Mitsubishi CP-9600D/DW
|
||||
Mitsubishi CP-D70DW
|
||||
Mitsubishi CP-D70DW and CP-D707DW
|
||||
Mitsubishi CP-D80DW
|
||||
Mitsubishi CP-K60DW-S
|
||||
Mitsubishi CP-D90DW
|
||||
|
@ -67,7 +67,6 @@
|
|||
Mitsubishi CP-3020D/DE and CP-3020DA/DAE
|
||||
Mitsubishi CP-9000DW, CP-9500DW, and CP-9600DW-S
|
||||
Mitsubishi CP-9800DW, CP-9800DW-S, CP-9810DW, and CP-9820DW-S
|
||||
Mitsubishi CP-D707DW
|
||||
Olmec OP900
|
||||
Shinko CHC-S6245 (aka Sinfonia CE1)
|
||||
Sony UP-CR10L (aka DNP DS-SL10)
|
||||
|
@ -655,9 +654,6 @@
|
|||
Mitsubishi CP-D80DW
|
||||
Mitsubishi CP-K60DW-S
|
||||
Fujifilm ASK-300
|
||||
|
||||
Untested but believed to work:
|
||||
|
||||
Mitsubishi CP-D707DW
|
||||
|
||||
Unsupported printers (Unknown VID/PID):
|
||||
|
|
|
@ -200,7 +200,9 @@ struct mitsu70x_jobstatus {
|
|||
uint8_t mecha_status[2];
|
||||
uint8_t temperature;
|
||||
uint8_t error_status[3];
|
||||
uint8_t reserved[6];
|
||||
uint8_t mecha_status_up[2];
|
||||
uint8_t temperature_up;
|
||||
uint8_t error_status_up[3];
|
||||
} __attribute__((packed));
|
||||
|
||||
struct mitsu70x_job {
|
||||
|
@ -796,9 +798,9 @@ static int mitsu70x_attach(void *vctx, struct libusb_device_handle *dev, int typ
|
|||
resp.lower.media_type = 0x0f;
|
||||
}
|
||||
|
||||
/* Figure out if we're a D707 with two decks */
|
||||
if (ctx->type == P_MITSU_D70X &&
|
||||
resp.upper.mecha_status[0] != MECHA_STATUS_INIT &&
|
||||
resp.upper.capacity != 0xffff)
|
||||
resp.upper.mecha_status[0] != MECHA_STATUS_INIT)
|
||||
ctx->num_decks = 2;
|
||||
else
|
||||
ctx->num_decks = 1;
|
||||
|
@ -1260,19 +1262,20 @@ done:
|
|||
list = dyesub_joblist_create(&mitsu70x_backend, ctx);
|
||||
|
||||
/* 6x4 can be combined, only on 6x8/6x9" media. */
|
||||
// XXX TODO: Don't combine if one deck is an exact match!
|
||||
// XXX what about splitting copies between decks?
|
||||
can_combine = 0;
|
||||
if (job->rows == 1218 ||
|
||||
job->rows == 1228) {
|
||||
if (ctx->medias[0] == 0xf ||
|
||||
ctx->medias[0] == 0x5 ||
|
||||
ctx->medias[1] == 0xf ||
|
||||
ctx->medias[1] == 0xf || /* Two decks possible */
|
||||
ctx->medias[1] == 0x5)
|
||||
can_combine = !job->raw_format;
|
||||
} else if (job->rows == 1076) {
|
||||
if (ctx->type == P_KODAK_305 ||
|
||||
ctx->type == P_MITSU_K60) {
|
||||
if (ctx->medias[0] == 0x4 ||
|
||||
ctx->medias[1] == 0x4)
|
||||
if (ctx->medias[0] == 0x4) /* Only one deck */
|
||||
can_combine = !job->raw_format;
|
||||
}
|
||||
}
|
||||
|
@ -1765,9 +1768,22 @@ top:
|
|||
if (ret)
|
||||
return CUPS_BACKEND_FAILED;
|
||||
|
||||
// XXX TODO: Goal here is to find a deck we can use!
|
||||
// so... get disposition of both decks.
|
||||
// figure out which decks are legal to use
|
||||
|
||||
/* Make sure temperature is sane */
|
||||
if (jobstatus.temperature == TEMPERATURE_COOLING) {
|
||||
INFO("Printer cooling down...\n");
|
||||
if (ctx->num_decks == 2)
|
||||
INFO("Lower deck cooling down...\n");
|
||||
else
|
||||
INFO("Printer cooling down...\n");
|
||||
sleep(1);
|
||||
goto top;
|
||||
}
|
||||
if (ctx->num_decks == 2 &&
|
||||
jobstatus.temperature_up == TEMPERATURE_COOLING) {
|
||||
INFO("Upper deck cooling down...\n");
|
||||
sleep(1);
|
||||
goto top;
|
||||
}
|
||||
|
@ -1875,7 +1891,7 @@ skip_status:
|
|||
hdr->jobid = cpu_to_be16(ctx->jobid);
|
||||
|
||||
/* Set deck */
|
||||
if (ctx->type == P_MITSU_D70X) {
|
||||
q if (ctx->type == P_MITSU_D70X) {
|
||||
hdr->deck = 0; /* D70 use automatic deck selection */
|
||||
/* XXX alternatively route it based on state and media? */
|
||||
} else {
|
||||
|
@ -1949,6 +1965,8 @@ skip_status:
|
|||
if (ret)
|
||||
return CUPS_BACKEND_FAILED;
|
||||
|
||||
// XXX need to examine status of the correct deck for the job!
|
||||
|
||||
/* See if we hit a printer error. */
|
||||
if (jobstatus.error_status[0]) {
|
||||
ERROR("%s/%s -> %s: %02x/%02x/%02x\n",
|
||||
|
@ -1973,6 +1991,7 @@ skip_status:
|
|||
jobstatus.job_status[2],
|
||||
jobstatus.job_status[3]);
|
||||
|
||||
/* Check for job completion */
|
||||
if (jobstatus.job_status[0] == JOB_STATUS0_END) {
|
||||
if (jobstatus.job_status[1] ||
|
||||
jobstatus.job_status[2] ||
|
||||
|
@ -2106,15 +2125,38 @@ static int mitsu70x_query_jobs(struct mitsu70x_ctx *ctx)
|
|||
INFO("JOB00 ID : %06u\n", jobstatus.jobid);
|
||||
INFO("JOB00 status : %s\n", mitsu70x_jobstatuses(jobstatus.job_status));
|
||||
INFO("Power Status: %s\n", jobstatus.power ? "Sleeping" : "Awake");
|
||||
INFO("Mechanical Status: %s\n",
|
||||
mitsu70x_mechastatus(jobstatus.mecha_status));
|
||||
if (jobstatus.error_status[0]) {
|
||||
INFO("%s/%s -> %s\n",
|
||||
mitsu70x_errorclass(jobstatus.error_status),
|
||||
mitsu70x_errors(jobstatus.error_status),
|
||||
mitsu70x_errorrecovery(jobstatus.error_status));
|
||||
|
||||
if (ctx->num_decks == 2) {
|
||||
INFO("Lower Deck Mechanical Status: %s\n",
|
||||
mitsu70x_mechastatus(jobstatus.mecha_status));
|
||||
if (jobstatus.error_status[0]) {
|
||||
INFO("%s/%s -> %s\n",
|
||||
mitsu70x_errorclass(jobstatus.error_status),
|
||||
mitsu70x_errors(jobstatus.error_status),
|
||||
mitsu70x_errorrecovery(jobstatus.error_status));
|
||||
}
|
||||
INFO("Lower Deck Temperature: %s\n", mitsu70x_temperatures(jobstatus.temperature));
|
||||
|
||||
INFO("Upper Deck Mechanical Status: %s\n",
|
||||
mitsu70x_mechastatus(jobstatus.mecha_status_up));
|
||||
if (jobstatus.error_status[0]) {
|
||||
INFO("%s/%s -> %s\n",
|
||||
mitsu70x_errorclass(jobstatus.error_status_up),
|
||||
mitsu70x_errors(jobstatus.error_status_up),
|
||||
mitsu70x_errorrecovery(jobstatus.error_status_up));
|
||||
}
|
||||
INFO("Lower Deck Temperature: %s\n", mitsu70x_temperatures(jobstatus.temperature_up));
|
||||
} else {
|
||||
INFO("Mechanical Status: %s\n",
|
||||
mitsu70x_mechastatus(jobstatus.mecha_status));
|
||||
if (jobstatus.error_status[0]) {
|
||||
INFO("%s/%s -> %s\n",
|
||||
mitsu70x_errorclass(jobstatus.error_status),
|
||||
mitsu70x_errors(jobstatus.error_status),
|
||||
mitsu70x_errorrecovery(jobstatus.error_status));
|
||||
}
|
||||
INFO("Temperature: %s\n", mitsu70x_temperatures(jobstatus.temperature));
|
||||
}
|
||||
INFO("Temperature: %s\n", mitsu70x_temperatures(jobstatus.temperature));
|
||||
// memory status?
|
||||
|
||||
#if 0
|
||||
|
@ -2267,7 +2309,7 @@ static const char *mitsu70x_prefixes[] = {
|
|||
/* Exported */
|
||||
struct dyesub_backend mitsu70x_backend = {
|
||||
.name = "Mitsubishi CP-D70 family",
|
||||
.version = "0.82",
|
||||
.version = "0.83",
|
||||
.uri_prefixes = mitsu70x_prefixes,
|
||||
.flags = BACKEND_FLAG_JOBLIST,
|
||||
.cmdline_usage = mitsu70x_cmdline,
|
||||
|
|
Loading…